Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Laboratory Medicine ; (12): 715-719, 2021.
Article in Chinese | WPRIM | ID: wpr-912463

ABSTRACT

Objective:To establish the allowable total error (TEa) of the national external quality assessment (EQA) program in line with the current quality level of serum folate measurement in China.Methods:The data of serum total folate test in the clinical laboratory of a hospital in Beijing in 2016 were collected, and the Stata SE 15 software was used for Monte Carlo simulation to obtain the false-negative rate under different bias and inaccuracy conditions. The Origin Pro 9.1 software was used to make the contour figure. The TEa of serum total folate test is derived based on the acceptable false-negative rate. National EQA data of serum total folate in 2020 were collected to calculate the pass rate of participating laboratories and the laboratory pass rate of quality control products at each level under the five TEa derived from the analysis performance on clinical outcomes, biological variation, and the evaluation criterion of national EQA.Results:Based on the influence of analytical performance on clinical outcomes, the TEa was 10%. Under this TEa, the pass rate of the first EQA program of serum total folate in 2020 was more than 80%, and the pass rate of the second time was 73.1%. Under the minimum (46.57%) and appropriate level of TEa (15.52%) derived from biological variation and national EQA evaluation criterion, the pass rate of serum total folate in the two EQA programs in 2020 exceeded 85%.Conclusion:The analytical performance of serum total folate in China cannot meet the requirements of TEa derived based on the effect of analytical performance on clinical outcomes. An appropriate level of TEa derived based on biological variation (15.52%) is suggested as the recommended criterion for the TEa of serum total folate test.

2.
Chinese Journal of Laboratory Medicine ; (12): 545-551, 2019.
Article in Chinese | WPRIM | ID: wpr-756465

ABSTRACT

Objective Accurate measurement of aldosterone is critical in the diagnosis of primary aldosteronism. We compared the harmonization of three assays including isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) and two chemiluminescence immunoassays (CLIAs:system A and system B) for the aldosterone measurement. Methods A total of 45 plasma samples, 4 quality control materials, 5 lyophilized bovine serums, and 3 fresh frozen human serum pools were measured by three assays respectively. Based on CLSI EP15-A3 rule, the precision was assessed by coefficient of variance. Deming regression and Bland&Altman plots was performed for method comparison, and correlation coefficient was calculated for concordance (CCC). Results All three methods met the performance criteria based on desirable biological variation for precision (<7.35%). System A showed a relevantly good correlation and comparability with ID-LC/MS/MS (R2=0.985, CCC=0.967), while System B showed relevantly bad correlations and comparability with both System A (R2=0.538, CCC=0.605) and ID-LC/MS/MS (R2=0.547, CCC=0.528).. However, the average relevant bias of two CLIAs exceeded the bias requirement derived from biological variation (18.60%). Conclusion Significant differences were found in the measurement of plasma aldosterone using ID-LC-MS/MS and two CLIAs, which urges the establishment of traceability hierarchy and improvement of reagents' specificity for standardization of aldosterone measurement in clinical settings.

SELECTION OF CITATIONS
SEARCH DETAIL